PENGARUH VARIASI TINGKAT PENYUMBATAN (CLOGGING) PADA BASKET STRAINER TERHADAP KINERJA POMPA : STUDI EKSPERIMENTAL

Ardiansyah, Saputra (2026) PENGARUH VARIASI TINGKAT PENYUMBATAN (CLOGGING) PADA BASKET STRAINER TERHADAP KINERJA POMPA : STUDI EKSPERIMENTAL. S-1 thesis, 021008 Universitas Tridinanti.

[img] Text (BAB. 1)
Repository BAB 1 (Ardiansyah Saputra).pdf - Published Version

Download (1MB)
[img] Text (BAB. 2)
BAB II Skripsi_compressed.pdf - Published Version
Restricted to Repository staff only

Download (216kB) | Request a copy
[img] Text (BAB. 3)
BAB III Skripsi_compressed.pdf - Published Version
Restricted to Repository staff only

Download (392kB) | Request a copy
[img] Text (BAB. 4)
BAB IV Skripsi_compressed.pdf - Published Version
Restricted to Repository staff only

Download (594kB) | Request a copy
[img] Text (BAB. 5)
BAB V_compressed.pdf - Published Version
Restricted to Repository staff only

Download (191kB) | Request a copy

Abstract

This study aims to analyze the effect of the level and position of clogging in the basket strainer on the pump performance and pump suction conditions. The study was conducted experimentally using the Shimida TCP-200 pump with a clogging variation of 0%, 25% top, 25% bottom, 50% top, 50% bottom, and 75%. The observed parameters included flow discharge, pressure drop, head loss, suction pressure, NPSH Available (NPSHa), and pump noise. Each variation was tested three times. The results showed that the pressure drop value was in the range of 13.89–22.35 kPa, while the head loss was in the range of 1,424–2,292 m. The highest pressure drop and head loss values were obtained in the upper 25% clogging condition . The absolute suction pressure was in the range of 71.09–80.91 kPa, while the NPSHa value was in the range of 7,059–7,996 m. The lowest discharge was obtained at a clogging condition of 75%, which was 54.87 L/min. The pump noise value was in the range of 79.53–80.70 dB and did not show a consistent increase in clogging increase. The results showed that the level and position of clogging affected the flow characteristics and suction conditions of the pump. The evaluation of cavitation potential was carried out based on changes in NPSHa and noise as supporting parameters, as NPSHr data of the pump were not available. Keywords: Basket Strainer, Clogging, Pressure Drop, Head Loss, NPSHa, Suction Pump, Cavitation.

Item Type: Thesis (S-1)
Subjects: T Technology > TJ Mechanical engineering and machinery
Divisions: Fakultas Teknik > S1 Teknik Mesin
Depositing User: Tn ARDIANSYAH SAPUTRA
Date Deposited: 24 Oct 2026 01:45
Last Modified: 24 Oct 2026 01:45
URI: http://repository.univ-tridinanti.ac.id/id/eprint/11552

Actions (login required)