ANALISA PERFORMA HEAT RECOVERY STEAM GENERATOR (HRSG) UNIT 1 DAN 3 DI PLTGU MUSI 2 PT. PURADAYA PRIMA PALEMBANG

yadi, Har (2020) ANALISA PERFORMA HEAT RECOVERY STEAM GENERATOR (HRSG) UNIT 1 DAN 3 DI PLTGU MUSI 2 PT. PURADAYA PRIMA PALEMBANG. S-1 thesis, 021008 Universitas Tridinanti Palembang.

[img] Text (BAB I)
step 1 cover bab 1, pengesahan, persetujuan, daftar pustaka.pdf - Published Version

Download (631kB)
[img] Text (BAB II)
BAB 2.pdf - Published Version
Restricted to Repository staff only

Download (875kB) | Request a copy
[img] Text (BAB III)
BAB 3.pdf - Published Version
Restricted to Repository staff only

Download (452kB) | Request a copy
[img] Text (BAB IV)
BAB 4.pdf - Published Version
Restricted to Repository staff only

Download (836kB) | Request a copy
[img] Text (BAB V)
BAB 5.pdf - Published Version
Restricted to Repository staff only

Download (215kB) | Request a copy

Abstract

Heat Recovery Steam Generator (HRSG) berfungsi untuk memanaskan air dan merubahnya menjadi uap panas (steam) yang bertemperatur dan bertekanan tinggi, lalu steam tersebut di alirkan untuk memutar Turbine Uap yang di kopel dengan Generator sehingga menghasilkan listrik sebagai hasil dari perputaran medan magnet dalam kumparan. HRSG memakai bahan bakar yang berasal dari Gas sisa dari Turbine Gas pada sistem PLTG sehingga menjadi suatu siklus gabungan atau combine cycle (PLTGU). Selama periode 2008 hingga 2020 PLTGU Musi 2 mengalami perubahan-perubahan, mulai dari penurunan efisiensi pada 2015, dan perubahan dari pola operasi pada tahun 2019. dengan pola operasi yang berbeda tersebut terlihat perbedaan pada tiap-tiap HRSG, terutama pada unit HRSG 1 dan HRSG 3 dengan input panas yang sama pada 513°C namun output yang dihasilkan berbeda. Oleh karena itu di lakukan analisa performa pada HRSG unit 1 dan 3, analisa dilakukan untuk menghitung laju perpindahan panas dan efisiensi pada HRSG. Hasil perhitungan diperoleh nilai laju perpindahan panas Q_keseluruhan pada HRSG 1 sebesar 9426,6091 Kw dan nilai Q_keseluruhan pada HRSG 3 sebesar 8776,9737 Kw, nilai efisiensi η HRSG 1 adalah 32,19 % dan η HRSG 3 adalah 29,98 %. Heat Recovery Steam Generator (HRSG) functions to heat water and convert it into hot steam (steam) with high temperature and pressure, then the steam is flowed to rotate the Steam Turbine coupled with the Generator to produce electricity as a result of rotating the magnetic field in the coil. . HRSG uses fuel derived from residual gas from Turbine Gas in the PLTG system so that it becomes a combined cycle (PLTGU). During the period 2008 to 2020 PLTGU Musi 2 underwent changes, starting from a decrease in efficiency in 2015, and a change in operating patterns in 2019. With these different operating patterns, there are differences in each HRSG, especially in HRSG 1 and HRSG units. 3 with the same heat input at 513 ° C but different output. Therefore, a performance analysis was performed on HRSG units 1 and 3, analysis was carried out to calculate the heat transfer rate and efficiency of the HRSG. The calculation results obtained that the Qoverall heat transfer rate value for HRSG 1 is 9426.6091 kW and the Qoverall value for HRSG 3 is 8776.9737 kW, the efficiency value of η HRSG 1 is 32.19% and η HRSG 3 is 29.98%.

Item Type: Thesis (S-1)
Subjects: T Technology > TJ Mechanical engineering and machinery
Divisions: Fakultas Teknik > S1 Teknik Mesin
Depositing User: haryadi haryadi haryadi
Date Deposited: 24 Oct 2020 06:43
Last Modified: 24 Oct 2020 06:45