Mauladi, Ari (2024) ANALISIS KETIDAK-SEIMBANGAN DAYA REAKTIF UNIT GENERATOR 403 DI STASIUN SUMPAL MEDCO ENERGI. S-1 thesis, 021008-Universitas Tridinanti Palembang.
Text (BAB I)
Bab 1 a.pdf - Published Version Download (719kB) |
|
Text (BAB II)
bab 2 ari - Published Version Restricted to Repository staff only Download (1MB) | Request a copy |
|
Text (BAB III)
bab 3 ari - Published Version Restricted to Repository staff only Download (416kB) | Request a copy |
|
Text (BAB IV)
bab 4 ari - Published Version Restricted to Repository staff only Download (572kB) | Request a copy |
|
Text (BAB V)
bab 5 ari - Published Version Restricted to Repository staff only Download (145kB) | Request a copy |
Abstract
ABSTRAK Generator sinkron, yang juga dikenal sebagai alternator, adalah perangkat listrik yang mengubah energi mekanik dari penggerak utama menjadi daya listrik AC pada tegangan dan frekuensi tertentu dengan tujuan supaya bisa di paralelkan satu dengan yang lainnya untuk menambah kapasitas. Motor sinkron beroperasi pada kecepatan yang konsisten yang dikenal sebagai kecepatan sinkron. Konstruksi Generator sinkron tiga phasa memiliki 2 jenis eksitasi yaitu eksitasi sendiri/PMG maupun eksitasi terpisah. System eksitasi inilah yang akan menentukan besarnya VAR yang akan di serap oleh generator pada saat bekerja secara parallel. Pada skripsi ini penulis melakukan Analisa pembagian beban reaktif pada tiga unit generator yang ada di Stasiun Sumpal Medco energi. Dimana pada saat 3 Unit GTG bekerja secara parallel dengan mode auto share maka salah satu unit generator 403 beban reaktif yang di serap adalah kurang lebih 49.76% berbeda jauh dengan 2 unit yang lain yang hanya menyerap di kisaran 25% masing-masing. Dari perhitungan dan Analisa di dapat nilai eksitasi unit 403 adalah 12% dengan GGL yang di bangkitkan sebesar 451 volt, sedang dua unit lainnya eksitasi di berikan hanya sebesar 6% dan GGL yang di bangkitkan sebesar 425 volt pada masing- masing generator. Untuk mendapatkan pembagian beban reaktif / kVAR yang seimbang maka masing-masing eksitasi unit adalah sebesar 8% dengan besar GGL yang di bangkitkan sebesar 434 volt. Kata Kunci : Generator Sinkron, Ketidak-Seimbangan VAR, GGL, Cosᵠ, eksitasi ABSTRACT Synchronous generators, also known as alternators, are electrical devices that convert mechanical energy from a prime mover into AC electrical power at a specific voltage and frequency in order to be paralleled to increase capacity. Synchronous motors operate at a consistent speed known as synchronous speed. The construction of a three-phase synchronous generator has 2 types of excitation, namely self-excitation/PMG and separate excitation. This excitation system will determine the amount of VAR that will be absorbed by the generator when working in parallel. In this thesis, the author conducted an analysis of the distribution of reactive loads on three generator units at the Sumpal Medco Energi Station. Where when 3 GTG units work in parallel with auto share mode, one of the generator units 403 absorbs approximately 49.76% of the reactive load, which is much different from the other 2 units which only absorb around 25% each. From the calculation and analysis, the excitation value of unit 403 is 12% with a generated GGL of 451 volts, while the other two units are given excitation of only 6% and the generated GGL is 425 volts on each generator. To obtain a balanced reactive load / kVAR distribution, each unit excitation is 8% with a generated GGL of 434 volts. Keywords: Synchronous Generator, VAR Imbalance, GGL, Cosᵠ, excitation
Item Type: | Thesis (S-1) |
---|---|
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Divisions: | Fakultas Teknik > S1 Teknik Elektro |
Depositing User: | Mr mauliadi somad |
Date Deposited: | 19 Oct 2024 05:07 |
Last Modified: | 19 Oct 2024 05:08 |
URI: | http://repository.univ-tridinanti.ac.id/id/eprint/9300 |
Actions (login required)
View Item |