Zulyanto, Z (2024) ANALISIS KEMAMPUAN PEMBEBANAN JARINGAN TEGANGAN MENENGAH PADA PENYULANG KURASH DI PT. PLN (Persero) DI UNIT INDUK PEMBANGKITAN SUMATERA BAGIAN SELATAN. S-1 thesis, 021008 Universitas Tridinanti.
![]() |
Text (BAB I)
Bab 1 zul-1.pdf Download (354kB) |
![]() |
Text (BAB II)
bab 2 zul.pdf Restricted to Repository staff only Download (529kB) | Request a copy |
![]() |
Text (BAB III)
bab 3 zuk.pdf Restricted to Repository staff only Download (629kB) | Request a copy |
![]() |
Text (BAB IV)
bab 4 zul.pdf Restricted to Repository staff only Download (615kB) | Request a copy |
![]() |
Text (BAB V)
bab 5 zul.pdf Restricted to Repository staff only Download (272kB) | Request a copy |
Abstract
ABSTRAK Pembebanan penyulang distribusi ini sangatlah penting karena berkaitan dengan kontinuitas penyediaan tenaga listrik. Namun, permasalahan yang sering terjadi di ruang lingkup jaringan distribusi tenaga listrik yakni terdapat penyulang yang pembebanannya melebihi kapasitas ratingnya. Ketika terjadi pembebanan yang berlebih, maka akan menyebabkan arus yang cukup besar mengalir pada penghantar, hal ini akan menyebabkan susut daya (losses) dan drop tegangan pada ujung jaringan, terlebih lagi jika jarak beban yang dilayani terlampau jauh. tujuan dari penelitian ini adalah untuk menganalisis kemampuan pembebanan jaringan tegangan menengah pada penyulang Kurash Di PT. PLN (Persero) Di Unit Induk Pembangkitan Sumatera Bagian Selatan. Hasil perhitunganFaktor beban pada Gardu Induk Pembangkitan Sumatera Bagian Selatan yang bersifat fluktuatif berpengaruhnya terhadap efisiensi Penyulang Kurash namun tidak signifikan hanya naik turun pada angka 0,20 pada rasio pembebanan terendah dan 0,24 pada rasio pembebanan tertinggi dan Rata – rata efisiensi pada pembebanan bulan Agustus 2023 yang terdapat pada Penyulang Kurash 150/20 kV 30 MVA Gardu Induk Pembangkitan Sumatera Bagian Selatan sudah di bawah standar SPLN 61:1997 yaitu 98.57%. Efisiensi tertinggi 98,69% sedangkan efisiensi terendah 98,22%. Kata kunci : Pembebanan Jaringan, Drop Tegangan, Penyulang Kurash, Rugi daya dan Arus Normal ABSTRACT The loading of distribution feeders is very important because it is related to the continuity of electricity supply. However, a problem that often occurs in the scope of the electric power distribution network is that there are feeders whose loading exceeds their rated capacity. When excessive loading occurs, it will cause quite a large current to flow in the conductor, this will cause power losses (losses) and voltage drops at the end of the network, especially if the distance between the load being served is too far. The aim of this research is to analyze the loading capability of the medium voltage network on the Kurash feeder at PT. PLN (Persero) in the Southern Sumatra Power Generation Unit. Calculation results: The load factor at the Southern Sumatra Generating Substation, which fluctuates, has an effect on the efficiency of the Kurash Feeder, but it is not significant, only increasing and decreasing at 0.20 at the lowest loading ratio and 0.24 at the highest loading ratio and the average efficiency for loading in August 2023 at the Kurash 150/20 kV 30 MVA Feeder at the Southern Sumatra Generating Substation is below the SPLN 61:1997 standard, namely 98.57%. The highest efficiency is 98.69% while the lowest efficiency is 98.22%.. Keywords: Network Loading, Voltage Drop, Kurash Feeder, Power Loss and Normal Current
Item Type: | Thesis (S-1) |
---|---|
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering |
Depositing User: | Zul Yanto Zul |
Date Deposited: | 14 Apr 2025 03:45 |
Last Modified: | 14 Apr 2025 03:45 |
URI: | http://repository.univ-tridinanti.ac.id/id/eprint/9852 |
Actions (login required)
![]() |
View Item |